Product characteristics |
Laser protection class |
2 |
Housing |
rectangular |
Electrical data |
Operating voltage [V] |
18...30 DC; (operating voltage "supply class 2" according to cULus) |
Current consumption [mA] |
< 150 |
Protection class |
III |
Reverse polarity protection |
yes |
Typ. lifetime [h] |
50000 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 2; Number of analogue outputs: 1 |
Outputs |
Total number of outputs |
2 |
Electrical design |
PNP |
Number of digital outputs |
2 |
Output function |
normally open / normally closed; (parameterisable) |
Max. current load per output [mA] |
200 |
Number of analogue outputs |
1 |
Analogue current output [mA] |
4...20; (IEC 61131-2) |
Max. load [Ω] |
250 |
Analogue voltage output [V] |
0...10; (IEC 61131-2) |
Min. load resistance [Ω] |
5000 |
Short-circuit protection |
yes |
Type of short-circuit protection |
pulsed |
Overload protection |
yes |
Detection zone |
Max. light spot width [mm] |
15 |
Max. light spot height [mm] |
15 |
Light spot dimensions refer to |
10 m |
Background suppression [m] |
0...19 |
Measuring/setting range |
Measuring range [m] |
0.2...10; (white paper 200 x 200 mm 90% remission) |
Sampling rate [Hz] |
1...50 |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis |
SIO mode |
yes |
Required master port type |
A |
Process data analogue |
2 |
Process data binary |
3 |
Min. process cycle time [ms] |
6 |
Supported DeviceIDs |
Type of operation |
DeviceID |
Default |
806 |
|
Operating conditions |
Ambient temperature [°C] |
-10...60 |
Protection |
IP 67 |